1. Chemical composition detection (What is the quality inspection standard of silicon metal 1101?)
- Silicon content: The silicon content of metal silicon 1101 is usually required to be above 99.99%, and it is an ultra-high purity silicon material used to produce products with high purity requirements (such as monocrystalline silicon and polysilicon).
- Iron content: Iron, as the main impurity element, must be strictly controlled. The content of iron in metal silicon 1101 is usually required to be no more than 0.1%.
- Aluminum content: The aluminum content has a great impact on the electrical properties and corrosion resistance of silicon, and the aluminum content of metal silicon 1101 should be less than 0.01%.
- Calcium content: As an impurity element, the presence of calcium will affect the mechanical strength and durability of silicon, and the content is required to be no more than 0.01%.
- Phosphorus content: Phosphorus is one of the harmful impurities in silicon, which will affect the electrical conductivity of silicon, and usually requires a phosphorus content of less than 0.001%.
- Sulfur content: The sulfur content should be strictly controlled, because it will increase the brittleness of silicon, and the sulfur content in metal silicon 1101 is required to be no more than 0.001%.
- Carbon content: Carbon impurities can affect the electronic properties of silicon, so a carbon content of less than 0.005% is required.
- Chlorine content: Chlorine content must be strictly controlled in the production of high-purity silicon, generally requiring less than 0.001%.
3. Physical performance test (What is the quality inspection standard of silicon metal 1101?)
- Particle size distribution: Silicon metal 1101 is usually processed into particles or powder, and its particle size distribution needs to meet the requirements of users. Typical particle size ranges from 1-10mm, and specific applications may require a more precise distribution.
- Density and purity uniformity: The density is required to be within the standard range to ensure that there are no obvious defects inside the material and that it has uniform physical properties.
- Inductively coupled Plasma Emission Spectroscopy (ICP-OES) : Used to detect trace elements in silicon, including impurities such as iron, aluminum, and calcium.
- Inductively coupled Plasma Mass Spectrometry (ICP-MS) : Precise determination of very low levels of impurity elements such as phosphorus and sulfur.
- Chemical analysis: Traditional wet chemical analysis is used to detect the purity of silicon, which can accurately determine the content of main elements and impurities.
- X-ray fluorescence Spectroscopy (XRF) : For the rapid detection of major elements and impurities in silicon, especially for quality control in the production process.
- Particle size analysis: The particle size distribution is determined by a laser particle size analyzer to ensure that it meets user requirements.